A conveyor that keeps tripping its overload relay on a Friday shift is how most reduction module decisions actually start. The motor checks out, the speed is wrong, and the gearbox that was ordered by motor frame size is running hot after two hours of continuous work. Nothing is broken. The module was simply picked from a catalogue column instead of from the load.
The short answer: size the module from output torque and duty cycle first, confirm the ratio second, and choose the gear type from the machine layout last. Get those three in that order and almost every catalogue becomes readable. Reverse the order, pick the gearbox first and then look for a reason to justify it, and you either pay for a unit that is far larger than the application needs or replace a unit that was never going to survive a year.
What follows are the eight checks that decide whether a reduction module holds up: torque rating, ratio, service factor, gear type, efficiency and thermal limits, mounting and shaft loads, backlash, and the environmental details that usually get left off the enquiry.
Step 1: Size From Output Torque, Not From the Motor
Start with the number the machine needs at the output shaft. If you know the driven load and its radius, torque is force multiplied by distance. If you know motor power and output speed, use this instead:
Output torque (Nm) = 9550 x motor power (kW) / output speed (rpm)
A 3 kW motor driving an output at 30 rpm gives roughly 955 Nm before any service factor is applied. For a uniformly loaded fan that may be plenty. For an inclined conveyor with lumpy feed, apply a factor of 1.5 and look for a module rated at about 1430 Nm at 30 rpm.
Two details catch people out. First, catalogue torque figures are tied to a specific ratio and output speed, so the same housing may be rated at 1200 Nm in one ratio and 900 Nm in another. Second, the figure that matters is the continuous rated torque, not the peak or emergency torque that appears in bold somewhere on the page. If the machine can start under full load, check breakaway torque separately, because a loaded belt or a press flywheel can demand two to three times the running torque at start-up.
Step 2: Match the Ratio to the Real Output Speed
Ratio is input speed divided by output speed, but the input speed has to be the real one. A 4-pole motor on 50 Hz is listed as 1500 rpm synchronous and actually turns near 1450 rpm under load. On 60 Hz the same motor sits around 1750 rpm. A 60:1 unit driven at 1450 rpm delivers 24.2 rpm, not a clean 25.
That few percent matters on machinery with fixed process timing, such as a filling line or an indexing conveyor. If the process truly needs an exact speed, correct it with a variable frequency drive or a pulley change rather than hunting for a ratio that does not exist.
Availability is the second check. Inline helical units commonly reach about 1:280 in three stages. A single-stage worm unit reaches 1:100 or beyond but loses efficiency fast as the ratio climbs. Two-stage combinations cover the middle ground with better efficiency than one large worm stage, at the cost of a longer housing.
Step 3: Turn the Duty Cycle Into a Service Factor
Service factor is where purchasing risk is really decided, and it is the line most often skipped when a buyer compares two quotations by price alone. It converts a nominal load into a design load.
SF 1.0 to 1.25 — centrifugal fans and pumps, light belt conveyors with steady feed, small agitators, packaging rolls.
SF 1.25 to 1.75 — conveyors with irregular feed, mixers, bucket elevators, crushers with a flywheel, machine tool feeds.
SF 1.75 to 2.5 — punch presses, hammer mills, choked-start elevators, reversing drives with high inertia.
Then adjust for how the drive is actually used. Running more than 10 hours a day, ambient above 40 °C, or more than 10 starts per hour each justify adding 0.1 to 0.2 to the factor. A module sized at exactly the calculated torque leaves no allowance for warm oil, a worn bearing, or a season of slightly heavier product.
A service factor is not a safety blanket. It is the difference between a module that runs at 60 °C for ten years and one that needs an oil change every six months.
Step 4: Pick the Gear Type From the Machine Layout
Before comparing stages, materials and prices, answer one mechanical question: does the output shaft need to be in line with the motor, or at 90 degrees to it? Rotating the drive direction changes the housing, the bearing arrangement, the oil system, the efficiency and the cost. Layout usually decides more than preference does.
Inline arrangements are served by helical geared motors, which run quietly, produce little vibration, and deliver roughly 98% efficiency per stage, about 96% for two stages and 94% for three. Foot-mounted and flange-mounted versions of the same frame cover most horizontal conveyor, mixer and fan duty. Lining up the full gear reducer range in one view is faster than reading datasheets one at a time, because ratio, efficiency and mounting options appear in the same columns.
The R series helical geared motor is the usual starting point for in-line reduction: a compact coaxially arranged unit built for continuous industrial duty, available with standard motor flanges and a range of output shaft options.
R Series Inline Helical Gearmotor for Continuous Industrial DutyA compact coaxial reducer with 1-3 stages, up to 18,000 Nm and 160 kW, suited to continuous in-line industrial drive duties.View Product →Step 5: Right-Angle Modules — Bevel, Worm or Hypoid
Three families compete when the shaft has to turn 90 degrees, and each one wins in a different situation.
- Helical-bevel: 94% to 96% efficiency, high torque capacity in a short housing, and backdrivable. The default choice when the drive runs continuously and energy cost is visible on the electricity bill.
- Worm: the shortest route to high ratios in a single stage, quiet, and usually self-locking above about 1:40. Efficiency falls into the 60% to 85% band depending on ratio, and heat becomes the limiting factor rather than gear strength.
- Hypoid: an offset bevel set that keeps much of a worm drive's compactness while running at 90% to 95% efficiency, which suits duty where a worm unit would sit too hot.
If the machine has to hold a raised load without a brake, or if the shaft arrangement leaves no room for a bevel housing, the worm family still wins on layout. Otherwise, compare the continuous thermal rating before comparing price. The K series helical bevel gearmotor is the common answer for right-angle industrial duty, with the output shaft above, below or beside the motor as the frame allows.
K Series Helical Bevel Gearmotor for Right-Angle Industrial DutyRight-angle helical-bevel reducer with 12 sizes, up to 50,000 Nm and 200 kW, offering compact efficient drive for space-constrained machinery.View Product →Step 6: Check Efficiency and Thermal Limits Together
Every stage costs something. Two helical stages lose around 4% of the input power; a single-stage worm at 1:60 can lose 30% or more. A 2.2 kW motor on that worm drive leaves roughly 1.5 kW at the output shaft, which means the real output torque is about a third lower than the simple motor-based calculation suggests. That is usually the moment a "cheaper" worm unit turns out to need a larger frame than the helical option it replaced.
The mesh is also where heat is generated, and heat is what actually ends the life of a continuously loaded worm reducer. Check two curves in the catalogue rather than one: mechanical rating at the chosen output speed, and thermal rating at the real ambient temperature. Where the thermal curve sits below the mechanical curve, the module is limited by cooling, not by gear strength, and options such as a fan, a larger housing or a different gear type are the only honest fixes.
Step 7: Mounting Position, Backlash and Shaft Loads
Mounting position is not cosmetic. A unit filled and vented for M1 horizontal installation will leak oil or starve its bearings if it is bolted vertically without the breather and oil level being changed to suit. Most modular gearboxes offer several positions, and the oil quantity differs between them. Confirm the position at the enquiry stage, not on site.
Overhung and axial loads are next. Catalogue radial load figures assume the load is applied at the middle of the shaft extension with a defined overhang. A sprocket pushed close to the housing, a long cantilever, or a belt pulled tight to stop slipping can push bearing load well past the rating. On shock-loaded drives, the fixing method matters as much as the size: a shaft-mounted speed reducer that survives shock loads is usually specified with a shrink disc rather than a keyed hollow shaft.
Backlash decides whether the module suits the job at all. General conveying and mixing tolerate 15 to 20 arcminutes. Positioning, indexing and reversing axes may need 3 to 5 arcminutes, and that usually means a different gear type or a higher-precision build rather than a different ratio.
Step 8: Linear Motion Needs a Different Module
When the output is a lift rather than a rotation, the selection changes shape. A screw lift converts motor rotation into linear travel, so the sizing inputs become load per unit, stroke, travel speed, duty cycle and the way the load is held when the motor stops.
Three points decide most screw lift projects. Self-locking behaviour matters if the load must stay up after power is removed, because not every ratio holds position. Buckling and screw stability matter on long strokes under compression, where the unsupported length grows quickly with the stroke. And on multiple-point lifting, units must be linked mechanically or driven from a common shaft so the platform stays level instead of twisting under uneven load.
The SWL series worm gear screw lifter covers this class of application, from single-unit raising and lowering to synchronised multi-unit arrangements driven from one motor.
SWL Series Worm Gear Screw Lifter for Industrial LiftingA self-locking worm gear screw lifter with models up to SWL35, designed for precise raising, lowering and synchronised multi-unit lifting arrangements.View Product →A Shortlisting Checklist Before You Request a Quote
- Required output torque in Nm at the required output speed, with the service factor already applied.
- Real input speed at 50 Hz or 60 Hz, and the tolerable output speed tolerance.
- Duty cycle in hours per day, starts per hour, and whether the drive reverses.
- Ambient temperature, dust, moisture, washdown or hazardous area classification.
- Inline or right-angle layout, plus the physical space around the shaft and housing.
- Efficiency chain from motor terminals to the driven machine, including couplings and belts.
- Thermal rating at the actual ambient, not at the catalogue reference condition.
- Mounting position M1 to M6 and the oil fill that goes with it.
- Radial and axial shaft loads measured with the real overhang and pulley or sprocket size.
- Backlash tolerance and any non-standard requirement: special shaft, flange, brake, encoder, or stainless finish.
Frequently Asked Questions
Q1: How do I know a service factor of 1.5 is enough?
Check what the driven machine does under its worst normal condition, not its design condition. A conveyor that occasionally runs half empty is uniform load; one that starts fully loaded with lumpy material is moderate shock. Add 0.1 to 0.2 if the drive runs more than 10 hours a day or sits in ambient above 40 °C.
Q2: Can the same gearbox run at 50 Hz and 60 Hz?
Mechanically yes, but both speed and torque change. At 60 Hz the motor runs faster, so the output speed rises by roughly 20% while available torque falls. Check the gearbox rating at the new output speed and confirm that the thermal rating still covers the duty, especially on worm units.
Q3: Does a self-locking worm reducer replace a brake?
It can hold a static load without power, but self-locking is a function of ratio, lead angle and vibration, and it is not a certified holding device. Where people work under a raised load, use a motor brake or a mechanical safety device in addition to the gearbox.
Q4: How much backlash should I specify for a positioning axis?
Specify the backlash the process can live with, then confirm the gear type can deliver it. General conveying and mixing tolerate 15 to 20 arcminutes. Indexing and reversing axes usually need 3 to 5 arcminutes, which points toward a precision build or a different gear family.
What to Send With an Enquiry
A supplier cannot size a module properly from motor power alone. Six data points remove almost all of the guesswork:
Output torque or the driven load and radius, plus output speed and the tolerance the process allows.
Motor power, poles, voltage and frequency, and whether a variable frequency drive is used.
Hours per day, starts per hour, shocks during operation, and ambient temperature at the installation point.
Mounting position, shaft arrangement, radial and axial loads with the overhang, and available space.
Non-standard requirements are also worth stating up front, because a custom housing, a special output shaft or a modified flange changes lead time. Deku Intelligent Drive builds standard helical, bevel, worm and screw lift units and also handles non-standard gear reducers, so an unusual ratio, mounting or shaft arrangement can be quoted as a variation rather than a dead end. Get the eight checks above in order and the quotation you receive will match the machine it has to drive.
05 Jun,2025